logo

Powerex Power PS1 DataSheet

No. parte # Fabricante Descripción Hoja de Datos
1
PS11011

Powerex Power
Application Specific Intelligent Power-Module

• Converter bridge for 3 phase AC-to-DC power conversion.
• Circuit for dynamic braking of motor regenerative energy.
• 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technology.
• Inverter output current capabil
Datasheet
2
PS11013

Powerex Power
Application Specific Intelligent Power-Module

• Converter bridge for 3 phase AC-to-DC power conversion.
• Circuit for dynamic braking of motor regenerative energy.
• 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technology.
• Inverter output current capabil
Datasheet
3
PS11014

Powerex Power
Application Specific Intelligent Power-Module

• Converter bridge for 3 phase AC-to-DC power conversion.
• Circuit for dynamic braking of motor regenerative energy.
• 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technology.
• Inverter output current capabil
Datasheet
4
PS11032

Powerex Power
Intellimod Module Application Specific IPM
□ Compact Packages □ 3 Phase Converter Bridge Built-in □ Integrated HVICs □ Direct Connection to DSP/CPU Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K L M N P Q Inches 2.91± 0.04 2.48± 0.04 0.34± 0.02 2.36 1.42 0.16 0.02 0.08 0
Datasheet
5
PS11035

Powerex Power
Intellimod Module Application Specific IPM
□ Compact Packages □ 3 Phase Converter Bridge Built-in □ Integrated HVICs □ Direct Connection to DSP/CPU Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K L M N P Q Inches 2.91± 0.04 2.48± 0.04 0.34± 0.02 2.36 1.42 0.16 0.02 0.08 0
Datasheet
6
PS11037

Powerex Power
Intellimod Module Application Specific IPM
□ Compact Packages □ 3 Phase Converter Bridge Built-in □ Integrated HVICs □ Direct Connection to DSP/CPU Applications: □ Small Motor Control □ Small Servo Motors □ General Purpose Inverters □ Pump and HVAC Motor Control Ordering Information: PS11037
Datasheet
7
PS12013-A

Powerex Power
Application Specific Intelligent Power-Module

• 3-Phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technologies.
• Circuit for dynamic braking of motor regenerative energy.
• Inverter output current capability Io (Note 1) : Type Name PS12013-A 100% load 1.8A (rm
Datasheet
8
PS12032

Powerex Power
Intellimod Module Application Specific IPM
□ Rectifier Bridge for 3-phase AC-to-DC Power Conversion □ 3-phase IGBT Inverter Bridge □ Integrated HVICs for Gate Drive, Protection and System Control Functions □ Built-in Thermistor □ Direct Connection to DSP/CPU Applications: □ Smart Motors □ Ge
Datasheet
9
PS11012

Powerex Power
Application Specific Intelligent Power-Module

• Converter bridge for 3 phase AC-to-DC power conversion.
• Circuit for dynamic braking of motor regenerative energy.
• 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technology.
• Inverter output current capabil
Datasheet
10
PS11015

Powerex Power
Application Specific Intelligent Power-Module

• Converter bridge for 3 phase AC-to-DC power conversion.
• Circuit for dynamic braking of motor regenerative energy.
• 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technology.
• Inverter output current capabil
Datasheet
11
PS11016

Powerex Power
Application Specific Intelligent Power-Module

• 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technologies.
• Circuit for dynamic braking of motor regenerative energy.
• Inverter output current capability IO (Note 1): Type Name 100% load 150% over load 11.0
Datasheet
12
PS11017

Powerex Power
Application Specific Intelligent Power-Module

• 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technologies.
• Circuit for dynamic braking of motor regenerative energy.
• Inverter output current capability IO (Note 1): Type Name 100% load 150% over load 17.0
Datasheet
13
PS11033

Powerex Power
Intellimod Module Application Specific IPM
□ Compact Packages □ 3 Phase Converter Bridge Built-in □ Integrated HVICs □ Direct Connection to DSP/CPU Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K L M N P Q Inches 2.91± 0.04 2.48± 0.04 0.34± 0.02 2.36 1.42 0.16 0.02 0.08 0
Datasheet
14
PS11034

Powerex Power
Intellimod Module Application Specific IPM
□ Compact Packages □ 3Phase Converter Bridge Built-in □ Integrated HVICs □ Direct Connection to DSP/CPU Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K L M N P Q Inches 2.91± 0.04 2.48± 0.04 0.34± 0.02 2.36 1.42 0.16 0.02 0.08 0.
Datasheet
15
PS11036

Powerex Power
Intellimod Module Application Specific IPM
□ Compact Packages □ 3 Phase Converter Bridge Built-in □ Integrated HVICs □ Direct Connection to DSP/CPU Applications: □ Small Motor Control □ Small Servo Motors □ General Purpose Inverters □ Pump and HVAC Motor Control Ordering Information: PS11036
Datasheet
16
PS12012-A

Powerex Power
Application Specific Intelligent Power-Module

• 3-Phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technologies.
• Circuit for dynamic braking of motor regenerative energy.
• Inverter output current capability Io (Note 1) : Type Name PS12012-A 100% load 1.2A (rm
Datasheet
17
PS12014-A

Powerex Power
Application Specific Intelligent Power-Module

• 3-Phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technologies.
• Circuit for dynamic braking of motor regenerative energy.
• Inverter output current capability Io (Note 1) : Type Name PS12014-A 100% load 3.4A (rm
Datasheet
18
PS12015-A

Powerex Power
Application Specific Intelligent Power-Module

• 3-Phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technologies.
• Circuit for dynamic braking of motor regenerative energy.
• Inverter output current capability Io (Note 1) : Type Name PS12015-A 100% load 4.8A (rm
Datasheet
19
PS12017-A

Powerex Power
Application Specific Intelligent Power-Module

• 3-Phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technologies.
• Circuit for dynamic braking of motor regenerative energy.
• Inverter output current capability Io (Note 1) : Type Name PS12017-A 100% load 7.2A (rm
Datasheet
20
PS12018-A

Powerex Power
Application Specific Intelligent Power-Module
Datasheet



logo    Desde 2024. D4U Semiconductor.   |   Contáctenos   |   Política de Privacidad