SGE2681-1G |
Part Number | SGE2681-1G |
Manufacturer | Microsemi (https://www.microsemi.com/) Corporation |
Description | This document describes and specifies the electrical and mechanical characteristics of the SGE2681-1G high voltage transformer for CCFL inverter power supplies. SGE2681-1G is the RoHS compliant and L... |
Features |
oltage Withstand 60Hz, Arc-detect enabled, 5 sec. min. 200µA max. leakage current Secondary to Core 2000VRMS min. ( 60sec) Primary to Core 1000VRMS min. Primary to Secondary 1000VRMS min. Items
WINDING SPECIFICATIONS
Primary Winding Sequence Wire Size & Type Number of Turns Winding Method Pin 2 – 3 2S – 3F #33, Single Insulation, 180°C 22 Bifilar Pin 3 – 4 3S – 4F #33, Single Insulation, 180°C 22 Secondary Pin 6 – 7 6S – 7F #46, Triple Insulation, 180°C 1600 PHYSICAL SPECIFICATIONS & WIRING DIAGRAM SGE2681-1G PART MARKING SGE - G XYZD A – SGE2681-1G: MSC PN, XYZ: Datecode (X:YR, YZ=WK)... |
Document |
SGE2681-1G Data Sheet
PDF 189.16KB |