logo

LTC1000-T LEM Current Transducer Datasheet

LTC1000-T CURRENT TRANSDUCER, IPN = 1000, MECHANICAL MOUNT = PANEL


LEM
LTC1000-T
Part Number LTC1000-T
Manufacturer LEM
Description Current Transducer LTC 1000-T For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current...
Features
• Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max
• Insulated plastic case recognized according to UL 94-V0
• Railway equipment. Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. voltage for partial discharge extinction Ve 200 1 : 5000 ± 15 .. 24 < 30 (@±24V) +IS 13.4 2) 1.5 3) > 2.8 Advantages






• Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency band...

Document Datasheet LTC1000-T datasheet pdf (63.07KB)
Distributor Distributor
Sager
Stock 0 In Stock
Price
3 units: 366.18 USD
9 units: 340.02 USD
21 units: 330.57 USD
45 units: 321.64 USD
87 units: 305.15 USD
BuyNow BuyNow BuyNow (Manufacturer a LEM Holdings SSA)




LTC1000-T Distributor

part
LEM Holdings SSA
LTC1000-T
CURRENT TRANSDUCER, IPN = 1000, MECHANICAL MOUNT = PANEL
3 units: 366.18 USD
9 units: 340.02 USD
21 units: 330.57 USD
45 units: 321.64 USD
87 units: 305.15 USD
Distributor
Sager

0 In Stock
BuyNow BuyNow





LTC1000-T Similar Datasheet

Part Number Description
LTC1000-S
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ ± 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case recognized according ...
LTC1000-SF
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-SF For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω mA V mA kV kV kV Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case rec...
LTC1000-SFC
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-SFC For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω mA V mA kV kV kV Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case re...




logo    Since 2024. D4U Semiconductor.   |   Contact Us   |   Privacy Policy