logo

LTC1000-SFC LEM Current Transducer Datasheet

LTC1000-SFC/SP2 CURRENT TRANSDUCER, IPN = 1000, MECHANICAL MOUNT = PANEL


LEM
LTC1000-SFC
Part Number LTC1000-SFC
Manufacturer LEM
Description Current Transducer LTC 1000-SFC For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary curre...
Features
• Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max
• Insulated plastic case recognized according to UL 94-V0
• Transducer delivered with feet and clamps Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. voltage for partial discharge extinction Ve 200 1 : 5000 ± 15 .. 24 < 30 (@±24V) +IS 13.4 2) 1.5 3) > 2.8 4)
• Railway equipment. Advantages






• Excellent accuracy Very good linearity Low temperature d...

Document Datasheet LTC1000-SFC datasheet pdf (64.36KB)
Distributor Distributor
Sager
Stock 0 In Stock
Price
6 units: 336.6 USD
24 units: 327.25 USD
42 units: 318.4 USD
90 units: 302.07 USD
BuyNow BuyNow BuyNow (Manufacturer a LEM Holdings SSA)




LTC1000-SFC Distributor

part
LEM Holdings SSA
LTC1000-SFC/SP2
CURRENT TRANSDUCER, IPN = 1000, MECHANICAL MOUNT = PANEL
6 units: 336.6 USD
24 units: 327.25 USD
42 units: 318.4 USD
90 units: 302.07 USD
Distributor
Sager

0 In Stock
BuyNow BuyNow





LTC1000-SFC Similar Datasheet

Part Number Description
LTC1000-S
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ ± 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case recognized according ...
LTC1000-SF
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-SF For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω mA V mA kV kV kV Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case rec...