logo

LTC1000-SF LEM Current Transducer Datasheet

LTC 1000-SF TRANSDUCER


LEM
LTC1000-SF
Part Number LTC1000-SF
Manufacturer LEM
Description Current Transducer LTC 1000-SF For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary curren...
Features
• Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max
• Insulated plastic case recognized according to UL 94-V0
• Transducer delivered with feet
• Railway equipment. Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. voltage for partial discharge extinction Ve 200 1 : 5000 ± 15 .. 24 < 30 (@±24V) +IS 13.4 2) 1.5 3) > 2.8 4) Advantages






• Excellent accuracy Very good linearity Low temperature drift Optimiz...

Document Datasheet LTC1000-SF datasheet pdf (62.59KB)
Distributor Distributor
DigiKey
Stock 0 In Stock
Price
30 units: 302336.6 KRW
12 units: 309155.9 KRW
6 units: 322795.84 KRW
BuyNow BuyNow BuyNow (Manufacturer a LEM Holdings SSA)




LTC1000-SF Distributor

part
LEM Holdings SSA
LTC 1000-SF
TRANSDUCER
30 units: 302336.6 KRW
12 units: 309155.9 KRW
6 units: 322795.84 KRW
Distributor
DigiKey

0 In Stock
BuyNow BuyNow
part
LEM Holdings SSA
LTC1000-SF
CURRENT TRANSDUCER, IPN = 1000, MECHANICAL MOUNT = PANEL
6 units: 235.95 USD
12 units: 219.09 USD
36 units: 213 USD
66 units: 207.25 USD
138 units: 196.62 USD
Distributor
Sager

0 In Stock
BuyNow BuyNow
part
LEM Holdings SSA
LTC 1000-SF
TRANSDUCER CURRENT 1000A HALL EFFECT,CLOSED LOOP
64 units: 521.84 USD
1 units: 559.11 USD
Distributor
New Advantage Corporation

64 In Stock
BuyNow BuyNow
part
LEM Holdings SSA
LTC 1000-SF
TRANSDUCER CURRENT 1000A HALL EFFECT,CLOSED LOOP
6 units: 391.3777 USD
1 units: 410.9466 USD
Distributor
Ozdisan Elektronik

80 In Stock
BuyNow BuyNow





LTC1000-SF Similar Datasheet

Part Number Description
LTC1000-S
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ ± 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case recognized according ...
LTC1000-SFC
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-SFC For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω mA V mA kV kV kV Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case re...
LTC1000-T
manufacturer
LEM
Current Transducer
Current Transducer LTC 1000-T For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd www.DataSheet4U.com 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω mA V mA kV kV kV Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case reco...




logo    Since 2024. D4U Semiconductor.   |   Contact Us   |   Privacy Policy